Helium-free MRI goes mainstream: Siemens Healthineers, Philips and Fujifilm expand the field

A 70 cm bore 1.5T system using 0.7 litres of helium, a sealed-magnet 3.0T platform, and a zero-helium 1.5T configuration are freeing MRI from helium refills and quench pipes.

Imaging Horizon Desk · · 3 min read

Conventional superconducting MRI magnets need large volumes of liquid helium, as well as quench pipes and periodic refills. In 2026 three manufacturers moved helium-light and helium-free designs further into the mainstream. MRI can now be sited in more places, installed faster and run more sustainably.

Key points

  • Siemens Healthineers MAGNETOM Flow (70 cm, 1.5T): FDA clearance announced January 2026. It uses 0.7 litres of liquid helium and has no quench pipe.
  • Philips BlueSeal Horizon (3.0T): which Philips presents as the first 3.0T magnet of its kind to work without helium top-ups. 7 litres of helium are permanently sealed in, and it needs no refills or vent pipe. Submitted for FDA 510(k) clearance; not yet available for sale.
  • Fujifilm ECHELON ZeroHelium (1.5T): introduced at ECR 2026. Its US debut is planned for RSNA 2026.

Siemens Healthineers MAGNETOM Flow: a wide bore with minimal helium

The 70 cm bore MAGNETOM Flow is a 1.5T platform with a closed helium circuit. Siemens Healthineers' DryCool technology means it needs only about 0.7 litres of liquid helium. Without a quench pipe and with a compact footprint, the company says it can reduce installation costs. Siemens Healthineers reports up to 56% lower annual energy consumption than its previous generation.

The system brings AI into the workflow:

  • myExam Assist and myExam Autopilot for automated, guided scan strategies
  • myExam Implant Suite for scanning patients with implants such as pacemakers
  • AI-based image reconstruction designed to shorten scans and improve image quality
  • New coils, including the BioMatrix Contour XL for whole-body imaging and a tiltable head-and-neck coil with optional integrated wireless audio

Philips BlueSeal Horizon: helium-free at 3.0T

At 1.5T, Philips' sealed-magnet approach is already well established. Philips says more than 2,500 BlueSeal systems are installed worldwide, which together have saved more than 7 million litres of liquid helium. BlueSeal Horizon brings the approach to 3.0T. About 7 litres of helium are permanently enclosed in the cryogenic circuit, compared with about 1,500 litres in a previous-generation magnet, and there are no refills or vent pipes.

The platform pairs the magnet with Philips' AI tools:

  • SmartPlanning, now extended to cardiac imaging, with automated planning in as little as 30 seconds
  • SmartSpeed Precise, combining sharper images with up to three times faster scanning
  • SmartReading, which brings cloud-based AI reading and reporting tools onto the MR system, starting with oncology and neurology

Philips has submitted BlueSeal Horizon SI, XI and ZI to the US FDA for 510(k) clearance. It is pending clearance and not yet available for sale.

Fujifilm ECHELON ZeroHelium

Fujifilm introduced its ECHELON ZeroHelium MRI at ECR 2026 in Vienna. It reduces helium demand from about 2,000 litres to none. Fujifilm is adding a ZeroHelium configuration to its Echelon Synergy 1.5T platform and planned the US debut for RSNA 2026 in Chicago.

Why it matters

For imaging departments, helium-light and helium-free magnets mean:

  • Easier siting, because there is no quench pipe, which opens up upper floors, outpatient centres and smaller towns
  • Supply resilience, because helium refills are no longer needed
  • Sustainability, through lower helium use and, on some platforms, lower energy use

For regions where helium logistics and infrastructure have limited MRI access, these systems could bring high-field imaging to many more patients.

helium-free MRIsustainabilitySiemens HealthineersPhilipsFujifilmMAGNETOM FlowBlueSeal HorizonECHELON